On the Victron MultiPlus-II 120 V and 2×120 V, the Low Battery and Overload LEDs flash together for a DC ripple warning. If both stay lit, excessive ripple has shut down the inverter. 120 V operating manual · 2×120 V operating manual
Battery cable documentation
Battery cable and fuse installation follows the Victron manual for the applicable MultiPlus-II variant and local rules. 120 V installation manual · 2×120 V installation manual
What Class T fuse ratings mean
Victron describes Class T fuses as suitable for lithium battery systems because of their high interrupt ratings. The interrupt rating is the largest fault current the fuse can safely stop. Continuous current and DC voltage are separate ratings. Victron Wiring Unlimited on DC fuses
DC ripple warnings and monitoring
Ripple is the AC component of the voltage at the inverter’s DC input. Victron’s Wiring Unlimited identifies VEConfigure as a tool that tracks ripple. Victron Wiring Unlimited on ripple
| Low Battery and Overload LEDs | Meaning |
|---|---|
| Flash together | Ripple pre-alarm. DC input ripple is too high. |
| Stay lit | Ripple alarm. Excessive ripple shut down the inverter. |
| Take turns flashing | The battery is nearly depleted and the load exceeds the inverter’s nominal output. |
The manuals describe all three patterns. 120 V LED indications · 2×120 V LED indications
Evidence and limits. The English online editions of Victron’s MultiPlus-II 120 V and 2×120 V manuals and Wiring Unlimited were checked on November 27, 2026. No hardware testing was performed.