At 25°C, the Victron MultiPlus-II 3000VA is rated for 2,400 W of continuous AC output. The 12V 4k raises that to 3,400 W, and the 5000VA models deliver 4,000 W. Choose the model that matches your battery voltage and AC format and covers your continuous load. Victron MultiPlus-II specifications
Evidence and limits. Victron Energy’s MultiPlus-II and MultiPlus-II 2x120V product pages and section 4.4 of the online MultiPlus-II 120V manual were checked on 2026-11-27. The units were not tested hands-on.
How Victron names the 3000VA, 4k, 4k5, and 5000VA
The 3000VA and 5000VA labels give the ratings in volt-amperes. The 120V 12/3000/120-50 is a 12V inverter/charger with a 3000VA rating, a 120 A maximum battery charge current, and a 50 A transfer switch. The 230V 48/4k5/55-32 is a separate 48V model rated for 4,000 W continuous at 25°C. Victron MultiPlus-II specifications
Victron’s model listings group this way by nominal battery voltage. MultiPlus-II listings · MultiPlus-II 2x120V listings
- 12V. The 3000VA and 4k come in 120V, 2x120V, and 230V variants. Victron also lists the 230V
12/5000/220-50. - 24V. The 3000VA comes in 120V, 2x120V, and 230V variants. The 5000VA comes in 120V and 230V variants.
- 48V. The 3000VA and 5000VA come in 120V and 230V variants. The 4k5 shown here is a 230V model.
North American 120V and 2x120V specification comparison
MultiPlus-II 120V single-phase models
The 120V models below are grouped by the model codes in Victron’s published specifications.
| Specification | 12/3000/120-50 | 24/3000/70-50 | 48/3000/35-50 | 12/4k/160-50 | 24/5000/120-95 | 48/5000/70-95 |
|---|---|---|---|---|---|---|
| Continuous output at 25°C | 2,400 W | 2,400 W | 2,400 W | 3,400 W | 4,000 W | 4,000 W |
| Peak output | 5,500 W | 5,500 W | 5,500 W | 6,000 W | 9,000 W | 9,000 W |
| Maximum battery charge current | 120 A | 70 A | 35 A | 160 A | 120 A | 70 A |
| Transfer switch rating | 50 A | 50 A | 50 A | 50 A | 95 A | 95 A |
| Weight | 19 kg | 19 kg | 19 kg | 22 kg | 29 kg | 32 kg |
MultiPlus-II 2x120V split-phase RV models
Victron lists these three 2x120V models for North American 50 A, 120/240V split-phase service. Victron MultiPlus-II 2x120V specifications
| Specification | 12/3000/120-50 | 12/4k/160-50 | 24/3000/70-50 |
|---|---|---|---|
| Continuous output at 25°C | 2,400 W | 3,400 W | 2,400 W |
| Peak output | 5,500 W | 6,000 W | 5,500 W |
| Maximum battery charge current | 120 A | 160 A | 70 A |
| Transfer switch rating | 50 A | 50 A | 50 A |
| Weight | 22 kg | 25 kg | 22 kg |
MultiPlus-II 230V specification comparison
Among the 230V models below, the 48V 4k5 matches the 5000VA’s 4,000 W continuous rating at 25°C. Its peak rating is 7,000 W, compared with 9,000 W for the 5000VA. Victron MultiPlus-II specifications
| Specification | 3000VA (12V / 24V / 48V) | 12/4k/160-32 | 48/4k5/55-32 | 5000VA (24V / 48V) |
|---|---|---|---|---|
| Continuous output at 25°C | 2,400 W | 3,400 W | 4,000 W | 4,000 W |
| Peak output | 5,500 W | 6,000 W | 7,000 W | 9,000 W |
| Maximum battery charge current | 120 A / 70 A / 35 A | 160 A | 55 A | 120 A / 70 A |
| Transfer switch rating | 32 A | 32 A | 32 A | 50 A |
| Weight | 19 kg for 24V and 48V | 22 kg | 22 kg | 30 kg |
Choose by continuous AC output
Compare the combined watts of loads that run at the same time with the continuous output rating for your voltage and AC format. For example, a hypothetical 2,800 W continuous load at 25°C exceeds the 3000VA model’s 2,400 W rating. It falls within the 12/4k’s 3,400 W rating and the 5000VA and 48/4k5 models’ 4,000 W ratings. Victron MultiPlus-II specifications
Shore power, transfer switches, and split-phase behavior
- PowerControl and PowerAssist. The MultiPlus-II can reduce battery charging to stay within a limited shore or generator supply. PowerAssist can supplement that supply with battery power during peak demand. Victron MultiPlus-II features
- Primary and auxiliary outputs. The primary output transfers to inverter power when AC input is lost. On single-phase 120V models, the auxiliary output shuts off during battery operation and resumes about two minutes after AC input returns. Victron lists a 32 A auxiliary output rating for the 120V 3000VA and 4k models. Victron MultiPlus-II features · Victron 120V manual
- 2x120V passthrough. A single 2x120V model supplies 240V only when fed by 120/240V split-phase shore power or a split-phase generator. The unit supplies 120V on both legs in inverter mode or on a single-phase 120V supply. Victron MultiPlus-II 2x120V features
Installation follows Victron’s manual for the specific model and local rules.
Who each MultiPlus-II tier suits
MultiPlus-II 3000VA
- Choose it for an RV or van whose continuous load fits 2,400 W at 25°C. The single-phase 120V models weigh 19 kg, and the 2x120V models weigh 22 kg. 120V ratings · 2x120V ratings
- Move up if your steady load exceeds that rating or your 12V system calls for a charger rated above 120 A. Victron MultiPlus-II specifications
MultiPlus-II 4k and 230V 4k5
- Choose the 12/4k when the 12V 3000VA falls short and the 4k’s 3,400 W at 25°C and 160 A charger meet your needs. The 2x120V variant is available for 50 A split-phase RV service. 120V and 230V ratings · 2x120V ratings
- Consider the 48/4k5 for a 48V battery and 230V AC if 4,000 W continuous at 25°C, a 32 A transfer switch, and 55 A maximum charging meet your needs. For a 50 A transfer switch or 70 A charger at those voltages, consider the 48V 5000VA. Victron MultiPlus-II specifications
MultiPlus-II 5000VA
- Choose it for up to 4,000 W continuous at 25°C with a 9,000 W peak rating. The 24V and 48V single-phase 120V models have a 95 A transfer switch. Victron MultiPlus-II specifications
- Check battery voltage first. The 120V 5000VA models are 24V and 48V. Victron lists the 12V 5000VA as a 230V model. Victron MultiPlus-II model listings
For additional Victron modular system guides as they are published, see the Mobile Inverter HQ guides index.