For a 12 V bank, start with the SmartSolar 75/15 MPPT charge controller for an array up to its nominal 220 W rating. For 24 V, shortlist the 100/30 for up to 880 W nominal. For 48 V, start with the 100/20 for up to 1,160 W nominal, or the 150/35 if you need a higher PV voltage limit or more charge current. Check the array’s voltage and current against the controller’s limits before choosing. 75/15 and 100/20 specs, 100/30 specs, 150/35 specs.
Compare SmartSolar ratings by battery voltage
In 100/30, the 100 is the maximum solar open-circuit voltage in volts and the 30 is the rated battery charge current in amps. The battery bank voltage is listed separately. A 48 V bank rules out both the 100/30 and 100/50. Victron’s model naming and compatibility table.
| SmartSolar | Bank voltages shown | Charge current | Max PV Voc | Max PV Isc | Nominal PV at 12 V | At 24 V | At 48 V |
|---|---|---|---|---|---|---|---|
| 75/15 | 12 V, 24 V | 15 A | 75 V | 15 A | 220 W | 440 W | N/A |
| 100/15 | 12 V, 24 V | 15 A | 100 V | 15 A | 220 W | 440 W | N/A |
| 100/20 | 12 V, 24 V, 48 V | 20 A | 100 V | 20 A | 290 W | 580 W | 1,160 W |
| 100/30 | 12 V, 24 V | 30 A | 100 V | 35 A | 440 W | 880 W | N/A |
| 100/50 | 12 V, 24 V | 50 A | 100 V | 60 A | 700 W | 1,400 W | N/A |
| 150/35 | 12 V, 24 V, 48 V | 35 A | 150 V | 35 A | 500 W | 1,000 W | 2,000 W |
| 150/45 | 12 V, 24 V, 48 V | 45 A | 150 V | 45 A | 650 W | 1,300 W | 2,600 W |
The table shows Victron’s ratings for 12 V, 24 V and 48 V banks. Voc means open-circuit voltage and Isc means short-circuit current. Victron says these controllers limit input power when more than the nominal PV power is connected. Check the maximum Voc and Isc independently. 75/15, 100/15 and 100/20 specs, 100/30 and 100/50 specs, 150/35 and 150/45 specs, Victron’s PV sizing guidance.
For a 12 V or 24 V bank, the 100/50 is a step up from the 100/30 when you need more charge current and the array stays within a 100 V Voc limit. For a 48 V bank, the 150/45 raises nominal PV power from 2,000 W on the 150/35 to 2,600 W while keeping the same 150 V Voc limit. 100/30 and 100/50 specs, 150/35 and 150/45 specs.
Check the array before buying
- Calculate cold open-circuit voltage. For identical panels, take the panel’s Voc and its temperature coefficient from the panel datasheet. Adjust the panel Voc for the coldest expected temperature, then multiply by the number of panels per series string. Use Victron’s sizing calculator to check the proposed layout. Skip any model whose maximum PV Voc is below the calculated string voltage. Victron’s PV array installation guidance, Victron’s series-voltage calculation, Victron MPPT Calculator.
- Check PV short-circuit current. For identical panels in identical strings, multiply the panel datasheet’s Isc by the number of parallel strings. Rule out any model whose maximum PV Isc is below that result. Victron’s parallel-current calculation.
- Check the voltage needed to start charging. For the models in the table, PV voltage must be more than 5 V above actual battery voltage at startup. Once charging starts, PV voltage must remain at least 1 V above battery voltage. Small-model specs, 100/30 and 100/50 specs, 150/35 and 150/45 specs.
- Match watts and charging amps. Add the rated wattage of all panels and compare it with the nominal PV rating in your bank’s column. Check your battery maker’s charge-current limit. On the 150/35 and 150/45, the Max charge current setting in VictronConnect can be reduced to suit the battery. Victron’s array power calculation, Victron’s battery settings guide.
When to move from 100 V to 150 V
Suppose your 24 V bank has an 880 W array whose cold Voc is above 100 V and below 150 V. The 100/30 matches the nominal wattage, but the array exceeds the controller’s PV voltage limit. The 150/35 fits those two checks with a nominal PV rating of 1,000 W and a 150 V PV Voc limit. Confirm the array’s Isc is at most 35 A, then check startup voltage and the battery’s charge-current limit. 100/30 specs, 150/35 specs, Victron’s battery settings guide.
If the array needs more PV voltage or charge current than the models in the table provide, compare the larger models’ cold and operating voltage limits before buying. Victron’s 150/60 to 250/70 specifications.
Evidence and limits. Victron’s English SmartSolar MPPT manuals for the model families in the table and its PV sizing guidance were checked November 27, 2026. The sizing steps were not run on hardware.